top of page
AIRFORCE-ONE.jpg

AirForce ONE空軍一號

AirForce ONE空軍一號

雲端調整實時監控軟件

空軍一號調整軟件是麥翠斯柏斯特計算機的核心調適軟件。

ECU.png

Free on official site; cable purchase required  to activate.

VAITRIX 擁有獨家 3D 調校介面,具備調整與偵測功能。可針對不同區段獨立設定並控制增壓值,依據引擎轉速與負載提供 255 個可調整區塊,每個區塊皆可在 -100 至 +100 之間設定,共有 200 段調整範圍。

兼顧效率與安全性的完整車輛調校方式。透過 3D Mapping 三維調校表與雲端範本,使用者不僅能依不同負載,分別設定各引擎轉速區間的調校數值,也能將額外的自訂 MAP 儲存至雲端伺服器,方便日後調整或再次套用。

Adjust-interface-3
MAP-under-1
MAP-under-1
MAP-under-2
MAP-under-2
MAP-under-3
MAP-under-3
MAP-under-4
MAP-under-4
MAP-under-5
MAP-under-5
MAP-under-6
MAP-under-6
MAP-under-7
MAP-under-7
MAP-under-8
MAP-under-8
MAP-under-9
MAP-under-9-1
Adjust-Interface-2
Adjust-interface-1
MAP-0-1
MAP-0
MAP-02-1
MAP-02
MAP-1-1
MAP-1
MAP-2-1
MAP-2
MAP-3-1
MAP-3
MAP-4-1
MAP-4
new

1.Cloud servers options

2.Data traffic record and cursor shapes 

3.Plug-in connection status and data access

4.Transmitting data to the plug-in from the computer

5.Automatically displays 

6.Programmable data system

7.Data and features settings

8.Map copy

OP-1

The highest and lowest
safe range of values

can be programmable, such as operating output signal and output response time. 

2

SWITCH CONTROL / METHANOL INJECTION MAPPING

SWITCH ON

SHUT OFF

Adjust-Interface-4-new
DUTY-1
SW-1
VALVE-OPEN
METHANOL-OPEN
VALVA-CLOSE
METHANOL-CLOSE

Injection switch on/off is based on X-axis engine rev and Y-coordinate output of load shaft. 1 stands for ON and 0 stands for OFF.  The status displays ON when switching on, and displays OFF when shutting off.

80% means large amount of methanol

20% means small amount of methanol

Methanol injection output power is based on X-axis engine rev and Y-coordinate output of the load shaft. The output power ranges from 0% to 100%. The larger the data is, the higher the output power.  0% means 0% duty cycle; 100% means full power 100% duty cycle.  

BATTERY VOLTAGE CORRECTION

Battery-Voltage

Automatically correct battery voltage can be adjusted to prevent different output timing due to unstable output voltage when the vehicle alternator is running. This can not only correct ineffective working hours, but also stabilize the system. 

BATTERY VOLTAGE-1
BATTERY VOLTAGE-2

When the battery voltage correction is turning on at 100%, the volume of
methanol can be injected the same as output power.

When the battery voltage correction is turning on at 50%, it will compensate 
for relative high and low voltages.

BATTERY VOLTAGE-3

When the battery voltage correction is turning on at 0%, the power output will 
not be calibrated. 

BP.png

BOOST PRESSURE SETTING

The maximum boost pressure can be set to prevent
the engine from being overcharged
.

LL.png

LOW LIQUID LEVEL AUTO SHUTDOWN SETTING

Enabling the auto shutdown function results in the
system automatically shutting down when the methanol
liquid level in the tank falls below the safe limit.

RP.png

CYLINDER CAPACITY SETTING

1, 2, 3, 4, 5, 6, 8 and 10 different engines speed
are supported.

BATTERY VOLTAGE CORRECTION

AIRFORCE-ONE--1.png

The display of data traffic can be turning on/off by selecting the below switch options from 1-10, so the adjustment of computer data can be more convenient. 

CLOUD MAPPING DATA DOWNLOAD

MAPPING-DATA

Car models and data can be selected through online cloud system. Multiple purposes in one machine make the performance setting more easily.

SAFETY-SWITCH-NEW
  • Vaitrix Facebook
  • Vaitrix X
  • VAITRIX Instagram
  • Vaitrix Line
  • Vaitrix Blogger
  • VAITRIX YouTube
  • VAITRIX Vimeo
VAITRIX 麥翠斯痞客邦部落格

© 2026 - Present Day by AET INDUSTRIAL CO., LTD All Right Reserved

經銷據點_按鈕_168x48_2x.png
bottom of page